description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Product Introduction

The CO₂ Air Source Heat Pump (Model HCYK-10CII) captures residual heat from ambient air through advanced compression and heat exchange technology, delivering high-temperature water for both domestic and industrial applications.

 

Dual Benefits

Simultaneous environmental cooling and hot water supply in one integrated energy-saving solution.

 

Proven Performance

Wide Operating Range

-25°C to 43°C

Stable heating in extreme cold

Superior Output

80°C Differential

Maximum hot water temperature

Energy Champio

COP 4.5

Reduces energy costs by 60%+

Quiet Operation

≤58dB(A)

Low noise level

 

European Trusted: Modular design for rapid deployment, reliability proven
in 1000+ projects.

 

Full Series for Every Need

Residential/Small Business  

Heavy Industrial

 HCES-3D

HCYK-10CII (This Model)

HCYK-1D

HCYK-20CII

HCYK-3D

HCYK-40CII

 

HGYJT2-30CII


Specification
Name CO₂ Air Sourcec Heat pump
Model HCYK-10CII
Power 3N~ 380V/50Hz
Heating Mode Once heating
Performance Nominal working condition Standard working condition
Ambient Temperature DB/WB: 7/6 ℃ DB/WB: 20/15 ℃
Inlet  Temperature 30  ℃ 15  ℃
Outlet  Temperature 80  ℃ 60  ℃
Heat Capacity 22300W 36500W
Power Input 9000W 8100W
COP 2.5 4.5
Hot Water Yield 0.38m³/h 0.69m³/h
Rated Current 16.1A
Maximum starting current 45A
Maximum power input 9000W
Refrigerant R744
Charge 7.5 kg
Noise ≤ 58db
Applicable Ambient Temperature -25~43 ℃
Sheet metal material Hot-dip galvanized cold rolled plate
Color Dermatoglyph Dark Grey (RAL7043)
Product Dimension 1472*1100*2308 mm
Net weight 480 kg

 

 

HCYK-10CII Heating Capacity and COP per Unit of Horsepower for Each Water Outlet Temperature under Various Ambient (or Water Source) Temperatures (Return Water Temperature: 30°C)

Ambient Temperature
(or Water Source Temperature) °C

Heating Capacity
and Energy Efficiency

Water Outlet Temperature °C

45

50

55

60

65

70

75

80

85

90

-30

Air Source Unit Heating Capacity (kW)

12.1

12.7

13

13.2

13.3

13.3

13.4

13.5

 

 

COP

1.75

1.71

1.7

1.7

1.69

1.67

1.65

1.64

 

 

-20

Air Source Unit Heating Capacity (kW)

14

14.8

15.1

15.2

15.2

15.4

15.5

15.6

 

 

COP

2.03

1.98

1.97

1.97

1.96

1.96

1.94

1.92

 

 

-10

Air Source Unit Heating Capacity (kW)

15.7

16.3

16.6

16.8

17

17.1

17.3

17.4

17.6

17.7

COP

2.21

2.2

2.2

2.19

2.19

2.18

2.17

2.16

2.1

2.02

0

Air Source Unit Heating Capacity (kW)

20.5

21.6

21.9

22.4

22.6

22.8

23.1

23.3

23.6

23.8

COP

2.73

2.71

2.7

2.69

2.69

2.68

2.64

2.61

2.56

2.52

10

Air Source Unit Heating Capacity (kW)

25.9

27.4

28

28.6

29

29.3

29.7

30.1

30.5

30.8

COP

3.45

3.42

3.41

3.38

3.33

3.3

3.25

3.19

3.11

3.04

20

Air Source Unit Heating Capacity (kW)

31.3

33.5

34.3

35.2

35.7

36.2

36.8

37.2

37.8

38.3

COP

4.42

4.4

4.34

4.25

4.16

4.09

3.98

3.93

3.8

3.69

30

Air Source Unit Heating Capacity (kW)

35.5

38

39.1

40.2

40.9

41.6

42.3

42.8

43.6

44.2

COP

5.58

5.44

5.29

5.15

5.02

4.92

4.77

4.65

4.46

4.32

35

Air Source Unit Heating Capacity (kW)

38.1

40.2

41

42.5

43.1

43.7

44.5

45.1

45.9

46.5

COP

6.05

5.83

5.68

5.47

5.32

5.21

5.09

4.98

4.8

4.68

Certificate